Model

 

1100NG

1100LPG

1150NG

1150LPG

Gas

Natural

Propane

Natural

Propane

Altitude (Ft.)*

0-4,500 feet*

0-4,500 feet*

Input Maximum (Btu/h)

28,000

28,000

30,000

30,000

Input Minimum (Btu/h)

13,000

13,000

16,000

16,000

Manifold Pressure (in w.c.)

3.5”

9.0”

4.0”

9.0”

Minimum Supply Pressure (in w.c.)

5.0

11.0

5.0

11.0

Maximum Supply Pressure (in w.c.)

10.0

14.0

10.0

14.0

Main Burner Injector Marking

850

300

850

360

Pilot Injector Marking

51

30

51

30

Min. Rate By-Pass Screw

185

125

195

135

H5

4004585-03

©2014, Miles Industries Ltd.

Gas Conversion Kit

1100NGK / PGK & 1150NGK / PGK

Installation Instructions

This appliance is certifi ed for use from 0–4500 feet. For 
altitudes above 4500 feet, see local codes.

Kit Contents

1 Pilot injector
1 Main burner elbow injector
1 Set of conversion labels
1 Minimum rate by-pass screw

Tools Required

•  Wrenches, to disconnect gas line
•  Phillips (+) screwdriver, to remove burner module
•  Small (jewelers size) fl at blade screwdriver, to set 

pressure

• Small fl at blade screwdriver, to release pressure tap 

on valve

•  Needle nose pliers, to remove by-pass screw
•  Hex (Allen) wrench, 4 mm or 5/32”, to remove pilot 

injector

•  Manometer, to set pressure when regulator is integral 

with valve

Specifi cations

Use with with 

Valor Models 1100/1150 Heaters ONLY

WARNING

This conversion kit shall be installed by 
a qualifi ed service agency in accordance 
with the manufacturer’s instructions and 
all applicable codes and requirements of 
the authority having jurisdiction. If the 
information in these instructions is not 
followed exactly, a fi re, explosion or pro-
duction of carbon monoxide may result 
causing property damage, personal injury 
or loss of life. The qualifi ed service agency 
is responsible for the proper installation of 
this kit. The installation is not proper and 
complete until the operation of the con-
verted appliance is checked as specifi ed in 
the manufacturer’s instructions supplied 
with the kit.

Use this manual in conjunction with the 
installation manual supplied with the 
appliance.

Содержание Valor H5 Series

Страница 1: ...Small jewelers size flat blade screwdriver to set pressure Small flat blade screwdriver to release pressure tap on valve Needle nose pliers to remove by pass screw Hex Allen wrench 4 mm or 5 32 to remove pilot injector Manometer to set pressure when regulator is integral with valve Specifications Use with with Valor Models 1100 1150 Heaters ONLY WARNING This conversion kit shall be installed by a ...

Страница 2: ... burner injector 1 Using two wrenches disconnect inlet to valve control 2 Remove 12 screws holding module plate to firebox base 3 Withdraw module from firebox 4 Supporting injector elbow unlock and remove pipe assembly remove injector locknut from inside manifold housing 5 Exchange injector elbow from kit verify the new injector before you install see Specifications table on page 1 Reverse the ass...

Страница 3: ...ing 4 Insert the replacement minimum rate by pass screw and hand tighten using a screwdriver Refer to the Specifications table on page 1 for proper by pass screw Note that the number is stamped on the barrel of the screw Re assemble module 1 To reinstall is a reversal of the procedure 2 Position and locate module in the firebox inserting the valve first be careful not to trap cables between firebo...

Страница 4: ...justment screw using a small jeweller s size flat blade screwdriver as shown below while the appliance is running at full input to produce manifold pressure as per Specifications table on page 1 4 Turn off the appliance remove the manometer and tighten the test tapping screw 5 Check all connections for leaks Reinstall the fuel bed To reinstall the fuel bed to the installation of the fireplace see ...

Страница 5: ...0 pieds Apport maximal Btu h 28 000 28 000 30 000 30 000 Apport minimal Btu h 13 000 13 000 16 000 16 000 Pression d admission en c e 3 5 9 0 4 0 9 0 Pression d alimentation minimum en c e 5 0 11 0 5 0 11 0 Pression d alimentation maximum en c e 10 0 14 0 10 0 14 0 Injecteur brûleur principal 850 300 850 360 Injecteur de veilleuse 51 30 51 30 Vis d indice minimum 185 125 195 135 AVERTISSEMENT Ce k...

Страница 6: ...e 2 Enlevez les 12 vis retenant la plaque du brûleur à la boîte de foyer et sortez la plaque du brûleur du foyer 3 En supportant l injecteur coude débranchez la conduite et enlevez l écrou de verrouillage de l injecteur de l intérieur du manifold 4 Remplacez l injecteur par celui fourni avec le kit de conversion assurez vous d avoir le bon injecteur avant de l installer consultez le tableau Indice...

Страница 7: ...ue en place par un joint torique de caout chouc Il peut être nécessaire de devoir forcer le joint hors de sa position ou d enlever la vis avec des pinces à bec effilé Réinstallez le module du brûleur 1 Procédez à l inverse pour réinstaller le brûleur 2 Placez la plaque du brûleur dans la boîte de foyer insérant la soupape en premier Faites attention de ne pas coincer les câbles et fils entre le fo...

Страница 8: ...nsultez le guide d installation du foyer pour réinstal ler les pièces du foyer ou pour continuer l installation Apposez les étiquettes de conversion 1 Completez les informations requises sur l étiquette Cet appareil a été converti le par et placez avec l étiquette Cette commande a été convertie 2 Apposez les étiquettes de conversion sur le fond de la caisse du foyer près de la carte d identificati...

Отзывы: