Error
Cause
Corrective action
Electronic unit defect
Check status LED’s of the power
supply (D111...D115, ref. to
„19.1 Additional Setting
Elements“)
Contact FMS customer service
Electronic unit does
not answer to
interface commands
The interfacesare not
supported yet
Contact FMS customer service
20.2
Unwind Brake Trouble shooting
Error
Cause
Corrective action
Brake gives maximum
torque („full braking“)
Controller is enabled, but
material is not tight
Tighten the material carefully to
build-up a material tension
Using pilot control, the
diameter signal gives „0“;
diameter sensor defect
Check diameter sensor and
wiring; replace if needed
Brake releases very
slow and with great
delay
Parameter
current limit
too high
Set parameter
current limit
correct depending on the brake
used
Pilot control does not
work as expected
Setup of pilot control
failed
Repeat setup of pilot control, ref.
to „10.3 Setup of pilot control“
Brake doesn’t brake
Fuse blown on brake
amplifier
Replace fuse on brake amplifier
20.3
Unwind Drive Trouble shooting
Error
Cause
Corrective action
Roller does stay when
enabling the
controller;
ev. material cracking
Parameter
Start limit
set
too high
Decrease parameter
Start limit
Roller rewinds fast
when enabling the
controller;
ev. material cracking
Parameter
Start limit
set
too low
Increase parameter
Start limit
Parameter
Start speed
set
too high
Decrease parameter
Start speed
Roller unwinds much
too fast when enabling
the controller
Using pilot control: The
diameter signal gives „0“;
diameter sensor defect
Check diameter sensor and
wiring; replace if needed
Pilot control does not
work as expected
Setup of pilot control
failed
Repeat setup of pilot control, ref.