Gain feedback 1
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores the value wasdetermined with special function
Calibration
while the digital input „switch range“ was OFF
(measuring range 1). Alternatively you can input a value calculated
using the formulas written under „9.3 Calibrating the measuring
amplifier“, if the material tension cannot be simulated.
Range:
0.100 to
9.000
Default:
1.000
Increment:
0.001
Unit:
[-]
Gain feedback 2
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores the value wasdetermined with special function
Calibration
while the digital input „switch range“ was ON
(measuring range 2). Alternatively you can input a value calculated
using the formulas written under „9.3 Calibrating the measuring
amplifier“, if the material tension cannot be simulated.
Range:
0.100 to
9.000
Default:
1.000
Increment:
0.001
Unit:
[-]
Nominal Force 1
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores the nominal force of the low range of the
double range force sensor. It is printed to the nameplate of the force
sensor.
Range:
1
to
9999
Default:
1000
Increment:
1
Unit:
[N, kN, cN]
Nominal Force 2
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores the nominal force of the high range of the
double range force sensor. It is printed to the nameplate of the force
sensor.
Range:
1
to
9999
Default:
1000
Increment:
1
Unit:
[N, kN, cN]
Unit of sensor
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores the measuring unit of the force sensor. It is
printed to the nameplate of the sensor.
Range:
N, kN, cN
Default: