Operating Manual CMGZ 622
44
Limit value 1
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
The digital output „Limit value 1“ will be activated if the threshold
value stored in this parameter is passed over respectively passed
under (according to setting in parameter
Limit 1 min / max
). If the
value stored here is zero, limit switch monitoring is inactive.
Range:
A force value can be input. The value consists of 4 digits. The
position of the decimal point depends on the parameter
Force of
sensor.
Default:
0
Unit:
[N, kN, cN] or [lb, klb, clb]
Limit 2 min / max
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
Identical
with
Limit 1 min / max
but this parameter acts to the digital
output „limit value 2“.
Range:
Min,
Max
Default:
Min
Limit value 2
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
Identical
with
Limit value 1
but this parameter acts to the digital
output „limit value 2“.
Configuration instrument
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter configures the current output signal.
Range:
0...20mA, 4...20mA
Default:
0...20mA
Scale instrument 1
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores which material tension feedback value will
give the maximum signal (10V and 20mA) at the output if measuring
range 1 is used (digital input „switch range“ = OFF).
Range:
A force value can be input. The value consists of 4 digits. The
position of the decimal point depends on the parameter
Force of
sensor.
Default:
-
Unit:
[N, kN, cN] or [lb, klb, clb]