Operating Manual CMGZ 622
56
Pilot output
Applies to:
Unwind brake
Unwind drive
Winding drive
Use:
This parameter stores the required torque as a percentage of the
maximum output value. The value is determined with special
function
Adjust pilot control
.
Range:
0
to
100
Default:
0
Increment:
1
Unit:
[%]
Pilot reference
Applies to:
Unwind brake
Unwind drive
Winding drive
Use:
This parameter stores the reference value corresponding to the
parameter
Pilot output
. The value is determined with special
function
Adjust pilot control
.
Range:
A force value can be input. The value consists of 4 digits. The
position of the decimal point depends on the parameter
Force of
sensor.
Unit:
[N, kN, cN] or [lb, klb, clb]
Pilot diameter
Applies to:
Unwind brake
Unwind drive
Winding drive
Use:
This parameter stores the diameter at which the adjustment of pilot
control was done. The value is determined with special function
Adjust pilot control
.
Range:
A diameter value can be input. The value consists of 4 digits.
Unit:
[mm] or [inch]