Operating Manual CMGZ 622
37
14.2
List of System Parameters
Parameter
Unit
Min
Max
Default
Language
English, French, Italian, German
Measuring System
Metric, US standard
Metric
Lowpass display
[Hz]
0.1
10.0
1.0
Identifier [-]
0
255 0
Baud rate
2400, 4800, 9600, 19200
9600
14.3
List of Parameters CMGZ622
Parameter
Applies
to
1)
Unit
Min
Max
Default
Control mode
b u w l
Unwind brake, Unwind drive,
Winding drive, Line drive
Unwind
brake
Offset feedback 1
b u w l
[Digit] –8000
8000
0
Offset feedback2
b u w l
[Digit] –8000
8000
0
Gain feedback 1
b u w l
[-]
0.100 9.000 1.000
Gain feedback 2
b u w l
[-]
0.100 9.000 1.000
Nominal force 1
b u w l
[N, kN, cN]
1
9999
1000
Nominal force 2
b u w l
[N, kN, cN]
1
9999
1000
Unit of sensor
b u w l
N, kN, cN
N
Sensitivity
b u w l
[mV/V] 0.1 3.0 1.8
1 or 2 force sensors
b u w l
[-]
1 2 1
Lowpass feedback
b u w l
[Hz] 0.1
200.0
50.0
Limit 1 min/max
b u w l
Min, Max
Max
Limit value 1
b u w l
2)
3)
0
Limit 2 min/max
b u w l
Min, Max
Min
Limit value 2
b u w l
2)
3)
-
Config. instrument
b u w l
0...20mA, 4...20mA
0...20mA
Scale instrument 1
b u w l
2)
3)
-
Scale instrument 2
b u w l
2)
3)
-
Pilot control
b u w _
No, Yes
No
Line speed overlay
_ _ _ l
No, Yes
No
Influence of PID
b u w l
[%] 0.1
100.0
100.0
PID configuration
_ u w l
PI, PID
PI
Proportional P1
b u w l
[-]
0.01 100.00 1.00
Integral I1
b u w l
[s]
0.01 100.00 1.00
Derivative D1
_ u w l
[s]
0.001 10.000 0.010