Operating Manual CMGZ 622
55
Internal reference 1 / 2 / 3 / 4
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores the internal reference value given with special
function
Edit ref. value
.
There are 4 different reference values available, depending on the
control parameter set which is active. The BCD digital inputs are
used for switching (ref. to „9.7 Switching the control parameters“).
Range:
A force value can be input. The value consists of 4 digits. The
position of the decimal point depends on the parameter
Force of
sensor.
Unit:
[N, kN, cN] or [lb, klb, clb]
Cal. dia. val 1
Applies to:
Unwind brake
Unwind drive
Winding drive
Use:
This parameter stores the first diameter value given with special
function
Adjust diameter
.
Range:
A diameter value can be input. The value consists of 4 digits.
Unit:
[mm] or [inch]
Cal. dia. signal 1
Applies to:
Unwind brake
Unwind drive
Winding drive
Use:
This parameter stores the first voltage value given with special
function
Adjust diameter
.
Range:
0.00
to
10.00
Default:
0.00
Increment:
0.01
Unit:
[V]
Cal. dia. val 2
Applies to:
Unwind brake
Unwind drive
Winding drive
Use:
This parameter stores the second diameter value given with special
function
Adjust diameter
. Description and function otherwise
identical with
Cal.dia.val 1
.
Cal. dia. signal 2
Applies to:
Unwind brake
Unwind drive
Winding drive
Use:
This parameter stores the second voltage value given with special
function
Adjust diameter
. Description and function otherwise
identical with
Cal.dia.signal 1
.