Operating Manual CMGZ 622
41
14.5
Description of the Parameters CMGZ622
The parameter changing mode is activated by pressing the
PARA
↵
key for 3 seconds.
The module
Params CMGZ622 1
is then searched with the
↑
↓
keys and selected with
the
PARA
↵
key (ref. also to fig. 19). Each measuring point has its own module with a
parameter set. Parameters not applying to the selected control mode are not shown in
the display.
Control mode
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter defines the type of actuator which is supported by
this parameter set.
Range:
Unwind brake, Unwind drive,
Default:
Unwind
Winding drive, Line drive
brake
Offset feedback 1
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores the value in [Digit] determined with special
function
Find offset
while the digital input „switch range“ was OFF
(measuring range 1). It is not necessary to note this parameter
because a new offset adjustment is done very easy; also when
changing the whole electronic unit.
The offset can also be inputted manually with the
↑
↓
←
keys.
Range:
–8000
to
8000
Default:
0
Increment:
1
Unit:
[Digit]
Offset feedback 2
Applies to:
Unwind brake
Unwind drive
Winding drive
Line drive
Use:
This parameter stores the value in [Digit] determined with special
function
Find offset
while the digital input „switch range“ was ON
(measuring range 2). It is not necessary to note this parameter
because a new offset adjustment is done very easy; also when
changing the whole electronic unit.
The offset can also be inputted manually with the
↑
↓
←
keys.
Range:
–8000
to
8000
Default:
0
Increment:
1
Unit:
[Digit]