Maintenance and servicing
122
Operating instructions VISCOPOWER
E
N
G
L
IS
H
Make sure that electrical connections are not damaged.
PTFE stators and the rotors are Ex-marked on the front. Only these may be used as
spare parts.
If the Ex symbol is no longer recognisable, the respective parts must be replaced.
11.2 Maintenance schedule
Component
Maintenance activity
O-rings
Regular visual inspection for wear
O-rings
Replace when worn
Mechanical seal
Regular visual inspection for wear
Mechanical seal
Replace when worn
Mechanical seal
Clean after each use
Progressive cavity pump
Visual inspection for leakage
Sliding surfaces of the mechanical seal
Lubricate after cleaning, before commissioning and after
prolonged standing time (recommended grease: Klüber-
synth UH1 14-151)
Fitting of the mechanical seal on the
shaft
Lubricate after cleaning, before commissioning and after
prolonged standing time (recommended grease: Klüber-
synth UH1 14-151)
Coupling
Regular visual inspections for wear
Progressive cavity pump
Clean after each use
Hose clamps and hose fittings
Regularly check for secure fitting
Gearbox
Regularly check for ease of movement and absence of
clearance and replace if necessary
Motor flange
Check bearings and freewheel regularly for ease of
movement and absence of clearance and replace if
necessary
Содержание F 570
Страница 133: ......
Страница 199: ...Anhang Appendix Annexe...
Страница 200: ......
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......
Страница 207: ......
Страница 208: ......
Страница 209: ......
Страница 210: ......
Страница 211: ......
Страница 212: ...FB 10 58083001_02_1122 100 DEF...