Technical data
Operating instructions VISCOPOWER
83
E
N
G
L
IS
H
3.2.8 Speed sensor
The speed sensor is suitable for use with FLUXTRONIC
®
.
DANGER
Explosion and fire hazard
Risk of death from explosions and fires when working in potentially explosive atmos-
pheres.
Read chapter 2.4
Working in potentially explosive atmospheres
.
The speed sensor must always be operated via intrinsically safe devices.
NOTICE
Mounting on a ferritic base affects the switching behaviour.
General information
Designation
Value
Inductive and capacitive loads
It is essential to provide contact protection
Pulses per revolution
4
EC conformity 2014/35/EU Low Voltage Di-
rective
CE
Electrical data
Designation
Value
Output type
Reed contact
Switching function
1 NO contact
Max. switching capacity
10 VA
Max. switching current
0.5 A
Max. transport current
1.0 A
Max. switching current
200 V
Max. contact resistance
0.1
Ω