Disassembly and cleaning
112
Operating instructions VISCOPOWER
E
N
G
L
IS
H
The following personal protective equipment must be used:
o
Hand protection
o
Protective footwear
o
Eye protection (depending on the pumped medium)
o
Respiratory protection (depending on the pumped medium)
The progressive cavity pump may only be disassembled by qualified and authorised
personnel.
Before disassembly, remove the motor from the progressive cavity pump.
All media must also be removed from the progressive cavity pump and properly
disposed of before disassembly.
Immerse the progressive cavity pump in a cleaning agent only up to the discharge
connection.
The power supply must be equipped with a residual-current circuit breaker.
10.2 Preparations
The following documents must be ready to hand before starting disassembly:
o
Drawing of the progressive cavity pump
o
Operating instructions of attachment parts
– Supplier documentation
Before starting disassembly, all components to be detached must be secured against
falling, overturning or shifting.
Have tools ready for disassembly.
Provide suitable tools and aids such as assembly tools, spanners, vice and collection
containers.
Make sure that all operating substances have been drained.
Before disassembly, empty the progressive cavity pump, hoses and fittings.
Tips for cleaning
Cleaning work must not be carried out inside the Ex-area.
Do not use solvents over large areas, e.g. for degreasing.
Observe material resistance.
Do not use aggressive cleaning agents.
Dispose of cleaning agents in accordance with applicable legal regulations.
Observe the safety data sheets of cleaning agents.
Do not use highly flammable or corrosive media for cleaning of the progressive cavity
pump.
Use suitable cleaning tools, e.g. a brush.
Thoroughly rinse the individual components after cleaning and sterilise them if
necessary.
In case of adhesive and hardening media, flush the progressive cavity pump, then
disassemble it and carefully clean the mechanical seal.
Always carry out a visual inspection and function check after each cleaning operation.
Carry out visual inspections, especially on internal threads and, in case of dirt, repeat
cleaning with a suitable tool and check again.
Содержание F 570
Страница 133: ......
Страница 199: ...Anhang Appendix Annexe...
Страница 200: ......
Страница 201: ......
Страница 202: ......
Страница 203: ......
Страница 204: ......
Страница 205: ......
Страница 206: ......
Страница 207: ......
Страница 208: ......
Страница 209: ......
Страница 210: ......
Страница 211: ......
Страница 212: ...FB 10 58083001_02_1122 100 DEF...