10. Go through all of the voltage adjustment points for ranges 10 V, 100 V, and 1000 V. Nominal
adjustment voltage is noted in parenthesis.
This completes this part of the adjustment.
DC Range 5000 V Adjustment
To adjust this dc range, see
1. Connect the high voltage source to the HV and COM terminals of the Product.
2. Connect the high voltage probe input parallel to the high voltage source output terminals.
3. Connect the multimeter and set the dc voltage function to the high voltage probe output.
4. Select
Range 5000V low (0V)
from calibration menu. Push the
Select
softkey.
5. Set the output voltage 0.0 V dc on the high voltage source and switch the output terminals
ON.
6. Push the
Write
softkey to confirm the new adjustment value.
7. Highlight
Range 5000V high (+5000 V)
and push the
Select
softkey.
8. Set the output voltage to 5000 V dc on the high voltage source and switch the output
terminals ON. The Product reads approximately nominal value.
9. Push the
Write
softkey to save the new value.