Flexball Italiana S.r.l.
49
►
Important 1:
if there are more command stations connected to the same CANBus network, each command
station must have a unique address. This unique address of the command station is defined by the
configuration of the dip-switches.
►
Important 2:
“command station 1” and “command station Fast Start-up Mode” cannot co-exist in the same
system: either you have a “Fast Start-up Mode” or “Command station 1”.
►
Important 3:
To configure the dip-switches of each command station, please refer to the installation
schemes reported from section 7.1. to section 7.5.
►
Important 4:
two engines command is configured from the factory to be mounted in systems with only one
actuator. This is the typical application where there are two engines and/or gearboxes with electronic interface
(like it is described in sections 7.4 and 7.5). In case of systems with two propulsion systems equipped with
mechanical engines and mechanical gearboxes, you need to use two mechanical actuators (installations
described at sections 7.1, 7.2 and 7.3). If this is the case, the command station must be re-configured as
described at section 4.4.