Flexball Italiana S.r.l.
82
14.3. Specific parameters
Display
code
Description
Values
Factory
value
Value shown on
display (factory value)
Note
A0
Push-pull cable movement
direction
1 .. 4
4
04
dI
Delay before disengaging
the gearbox
0 .. 9,9 s
0,0 s
00
dA
Delay on the throttle
0 .. 9,9 s
0,0 s
00
PP
Proportional coefficient
0 .. 99
40
40
These parameters
must not be
changed
PI
Integral coefficient
0 .. 99
0
00
CP
CANBus protocol
1-99
0
00
See 17.2.2.
L1
These parameters are present only in systems with electronic engine (ECU)
and/or electric with electrical engine inverter driven. Parameters to define the
voltage output interface will be detailed at section 14.3.2.
H1
L2
H2
L3
H3
L4
H4
CC
To be used for the check-up of the internal CANBus communication
14.3.1. Parameters to configure the voltage output signal for electronic engines
For installations with electronic engine or hybrid engine
(engine driven by a frequency converter), it is necessary to
set the minimum and maximum voltage output. Voltage
signal profile is defined through parameters L*, and H*,
where “*” means 1,2,3,4.
►
Important:
the graphic on the right represents the
voltage profile defined by parameters L, H. Changes of
factory values could cause a system malfunctioning. Before
making any changes, contact our technicians.
Corsa della leva
Control lever stroke
V
L*
H*