Falcon R-Class | User Guide
34
Web GUI: Monitor > Ports > SFP Op Range
Figure 4-17: Operational Range
Table 4-14: SFP Operational Range Parameters
Port
The physical port in which the SFP is installed
Status
The status of the SFP port:
grey
=unplugged
Red
=when SFP is plugged and operational;
Green
when the SFP is
connected to another similar SFP (installed in another device)
RX Power
Module's allowed receive optical power range [dBm].
TX Power
Module's allowed transmit optical power range [dBm]
Temperature
Module's allowed internal temperature range.
Bias Current
Module's allowed transmitter bias current range [mA].
Supply voltage
Module's allowed supply voltage range [V].
SFP Monitoring
This section shows SFP digital diagnostic information
Web GUI: Monitor > Ports > SFP Monitor
Figure 4-18: SFP Monitoring
Table 4-15: SFP Monitoring Parameters
RX Power
Modules receive optical power [dBm].
TX Power
Modules transmit optical power [dBm].