Falcon R-Class | User Guide
307
125VDC Connection: In this case, the supplied AC cable allows the connection to an external DC
source of 125VDC.
DC Power Supplies
Connect DC line voltage using the power supply cords provided (alternatively you may use other
18AWG three wire cord). R Class devices will accept any line voltage from 20 to
̶
60VDCThere is no
ON/OFF switch on the device. When the power is connected to the device, the device is ON. This will
be indicated by the Power (PWR) LED lit green on the front panel.
Note: The earthen conductor of power cord must be grounded.
̶
20 to
–
60VDC Power Connection
The rear panel is equipped with a suitable screw connection (ST connector).
Figure 7-10: Falcon-RX series DC PS rear panel ST connector
DC powered models
:
Required current rating = 2A
CAUTION DOUBLE POLE FUSING
Verify that the DC-Mains provide a 2 Amp double pole circuit breaker. Required power conductor
size = at least 0.75mm² for flexible cable or 1mm² for non-flexible. Power Consumption (AC and DC
Power Supplies):
•
Falcon-RX
o
Maximum <12W
o
Typical: <10W
•
nFalcon-R:
o
Maximum <20W
o
Typical: <15W
•
Falcon-RX:
o
Maximum <60W
o
Typical: <50W
Falcon-RX device include Dual redundant, hot swappable power supplies
Содержание Falcon-RX/812/G/A
Страница 1: ...Falcon R Class User Guide Falcon RX Software version 8 0 20 www fibrolan com...
Страница 11: ...Falcon R Class User Guide 11 2 System Description 2 1 Block Diagram Figure 2 1 R Class functional block diagram...
Страница 86: ...Falcon R Class User Guide 86 Web GUI Configuration QoS DSCP Translation Figure 4 58 DSCP Translation...
Страница 221: ...Falcon R Class User Guide 221 Web GUI Configuration LLDP LLDP MED Figure 4 162 LLDP MED Configuration displays...