Falcon R-Class | User Guide
150
4.9
SyncCenter Configuration
Overview
SyncCenter is a unique feature developed by Fibrolan, which clearly visualizes the
system’s
clocks
and timing flows. It allows the high-level configuration and monitoring of inputs, outputs and
behavior.
Each one of the different inputs and outputs (e.g. PTP, SyncE) is configured and monitored in their
own respective detailed pages, but the overall control and relationship between them is handled by
SyncCenter.
Furthermore, SyncCenter allows both General and Hybrid modes. In General mode all clocking
domains (frequency, phase and ToD) are control by the same input(s) (e.g. GNSS), while the Hybrid
mode allows each domain to operate independently of the others (e.g. as a BC, with both PTP and
SyncE).
Mode Configuration
This section enables the configuration of the device's clocking system, with sync reference sources,
outputs and overall state.
The possible clock reference inputs (sync source) to the SyncCenter are: SyncE, PTP, NTP, GNSS, ToD,
TDM and External (1PPS and 10MHz). The SyncCenter will output the required sync clock according
to reference quality and priority.
Web GUI: Configuration > Timing > SyncCenter
Figure 4-93: Mode selection
When SyncCenter mode is set to Hybrid split clocking domain option appears
Sync Source Configuration
Figure 4-94: Sync Source display
Up to 5 different Sync sources cab be configured including SyncE, PTP, NTP, GNSS, ToD, TDM and
External. Source priority can be set according to ID (default) of quality level.
Содержание Falcon-RX/812/G/A
Страница 1: ...Falcon R Class User Guide Falcon RX Software version 8 0 20 www fibrolan com...
Страница 11: ...Falcon R Class User Guide 11 2 System Description 2 1 Block Diagram Figure 2 1 R Class functional block diagram...
Страница 86: ...Falcon R Class User Guide 86 Web GUI Configuration QoS DSCP Translation Figure 4 58 DSCP Translation...
Страница 221: ...Falcon R Class User Guide 221 Web GUI Configuration LLDP LLDP MED Figure 4 162 LLDP MED Configuration displays...