3. Diagnosis and error treatment
3−15
Festo P.BE−CPX−FB23−EN en 0308NH
Bit
Diagnostic information
with 1−signal
Description
0
Fault at valve
Module type on which a
fault has occurred
1
Fault at output
fault has occurred
2
Fault at input
3
Fault at analogue module/
function module
4
Undervoltage
Type of fault
5
Short circuit/overload
6
Wire fracture
7
Other faults
Tab.3/4:
Overview of status bits
If all status bits supply a 0−signal, no fault will be registered.
If various faults occur simultaneously on various types of
modules, they cannot be classified via the status bits. If
necessary, faults can be clearly defined via the I/O diagnostic
interface.
Further instructions on the function and content of the status
bits can be found in the CPX system manual.
Содержание CPX-FB23
Страница 2: ......
Страница 4: ...Contents and general instructions II Festo P BE CPX FB23 EN en 0308NH...
Страница 15: ...Installation 1 1 Festo P BE CPX FB23 EN en 0308NH Chapter 1...
Страница 45: ...Commissioning 2 1 Festo P BE CPX FB23 EN en 0308NH Chapter 2...
Страница 86: ...2 Commissioning 2 42 Festo P BE CPX FB23 EN en 0308NH...
Страница 87: ...Diagnosis and error treatment 3 1 Festo P BE CPX FB23 EN en 0308NH Chapter 3...
Страница 104: ...3 Diagnosis and error treatment 3 18 Festo P BE CPX FB23 EN en 0308NH...
Страница 105: ...Technical appendix A 1 Festo P BE CPX FB23 EN en 0308NH Appendix A...
Страница 117: ...Index B 1 Festo P BE CPX FB23 EN en 0308NH Appendix B...
Страница 118: ...B Index B 2 Festo P BE CPX FB23 EN en 0308NH Contents B Index B 1 B 1 Index B 3...