1. Installation
1−27
Festo P.BE−CPX−FB23−EN en 0308NH
Please note
In order to comply with protection class IP65/IP67:
·
Fit the DIL switch cover.
·
Seal the service interface with the protective cap
supplied.
·
Use the Festo sub−D plug.
Note that only the Festo sub−D plug guarantees
compliance with protection class IP65/IP67.
Connecting with sub−D plugs of other manufacturers
Connecting with sub−D plugs of other manufacturers:
·
Replace the two flat screws with bolts
(type UNC4−40/M3x6).
·
Connect the cable screening/shield to the plug housing.