![FE FRENIC-Multi series Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/fe/frenic-multi-series/frenic-multi-series_instruction-manual_3750705092.webp)
5-17
Examples
:
(linear) V/f pattern
Normal
V/f pattern with two non-linear points
F07
F08
E10
E11
Deceleration Time 1
Acceleration Time 1
Acceleration Time 2
Deceleration Time 2
F07 spec
the maxi
decreases f
ifies the acceleration time, the length of time the frequency increases from 0 Hz to
mum frequency. F08 specifies the deceleration time, the length of time the frequency
rom the maximum frequency down to 0 Hz.