3-4
3.3 Running
Mode
When the inverter is turned on, it automatically enters Running mode in which you can:
(1) Monitor the running status (e.g., output frequency and output current),
(2) Configure the reference frequency and other settings,
(3) Run/stop the motor, and
(4) Jog (inch) the motor.
3.3.1 Monitoring the running status
In Running mode, the eleven items listed below can be monitored. Immediately after the inverter is
turned on, the monitor item specified by function code E43 is displayed. Press the
key to switch
between monitor items. For details of switching the monitor item by using the
key, refer to
"Monitor of running status" in Running mode in Figure 3.1.
Table 3.3 Monitoring Items
Monitor items
Display
sample on
the LED
monitor *1
LED indicator
: on,
: off
Unit
Meaning of displayed value
Function
code data
for E43
Speed monitor
Function code E48 specifies what to be displayed on the LED monitor
and LED indicators.
0
Output frequency
(before slip
compensation)
5*00
Hz
A
kW
Hz
Frequency actually being output
(E48 = 0)
Output frequency
(after slip
compensation)
5*00
Hz
A
kW
Hz
Frequency actually being output
(E48 = 1)
Reference
frequency
5*00
Hz
A
kW
Hz
Reference frequency being set
(E48 = 2)
Motor speed
1500
Hz
A
kW r/min
P01
120
×
(Hz)
frequency
Output
For motor 2, read P01 as A15.
(E48 = 3)
Load shaft speed
30*0
Hz
A
kW r/min
Output frequency (Hz)
×
E50
(E48 = 4)
Line speed
30*0
Hz
A
kW m/min
Output frequency (Hz)
×
E50
(E48 = 5)
Constant feeding
rate time
50
Hz
A
kW
min
E39
×
(Hz)
frequency
Output
E50
(E48 = 6)
Output current
1"34
Hz
A
kW
A
Current output from the inverter
in RMS
3
Output voltage *2
200u
Hz
A
kW
V
Voltage output from the inverter
in RMS
4
Calculated torque
50
Hz
A
kW
%
Motor output torque in %
(Calculated value)
8
Input power
1*25
Hz
A
kW
kW
Input power to the inverter
9