5-6
(C code continued)
Code
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer to
page:
C31
-5.0 to 5.0
0.1
%
Y*
Y
0.0
5-50
C32
(Gain) 0.00 to 200.00 *1
0.01
%
Y*
Y
100.0
5-27
C33
(Filter time constant) 0.00 to 5.00
0.01
s
Y
Y
0.05
5-50
C34
(Gain base point) 0.00 to 100.00 *1
0.01
%
Y*
Y
100.0
5-27
C35
(Polarity)
0: Bipolar
-
-
N
Y
1
-
1: Unipolar
C36
-5.0 to 5.0
0.1
%
Y*
Y
0.0
5-50
(C1 function)
(Offset)
C37
(Gain) 0.00 to 200.00 *1
0.01
%
Y*
Y
100.0
5-27
C38
(Filter time constant) 0.00 to 5.00
0.01
s
Y
Y
0.05
5-50
C39
(Gain base point) 0.00 to 100.00 *1
0.01
%
Y*
Y
100.0
5-27
C41
-5.0 to 5.0
0.1
%
Y*
Y
0.0
5-50
(V2 function)
(Offset)
C42
(Gain) 0.00 to 200.00 *1
0.01
%
Y*
Y
100.0
5-27
C43
(Filter time constant) 0.00 to 5.00
0.01
s
Y
Y
0.05
5-50
C44
(Gain base point) 0.00 to 100.00 *1
0.01
%
Y*
Y
100.0
5-27
C50
Bias (Frequency command 1)
0.00 to 100.00 *1
0.01
%
Y*
Y
0.00
(Bias base point)
C51
Bias (PID command 1)
-100.00 to 100.00
-
(Bias value)
0.01
%
Y*
Y
0.00
C52
(Bias base point) 0.00 to 100.00 *1
0.01
%
Y*
Y
0.00
C53
0: Normal operation
-
-
Y
Y
0
(Frequency command 1)
1: Inverse operation
Selection of Normal/Inverse Operation
Analog Input Adjustment for [12]
(Offset)
Analog Input Adjustment for [C1]
Analog Input Adjustment for [C1]
Name
Data setting range
P codes: Motor 1 Parameters
Code
Incre-
ment
Unit
Change
when
running
Data
copying
Default
setting
Refer to
page:
P01
2 to 22
2
poles
N
Y1
Y2
4
5-51
P02
(Rated capacity)
0.01
0.01
kW
HP
N
Y1
Y2
Rated
capacity of
motor
P03
(Rated current) 0.00 to 100.0
0.01
A
N
Y1
Y2
Rated value
of Fuji
standard
motor
P04
(Auto-tuning)
0: Disable
-
-
N
N
0
1:
2:
P05
(Online tuning)
0: Disable
-
-
Y
Y
0
1: Enable
P06
(No-load current) 0.00 to 50.00
0.01
A
N
Y1
Y2
Rated value
of Fuji
standard
motor
P07
(%R1) 0.00 to 50.00
0.01
%
Y
Y1
Y2
Rated value
of Fuji
standard
motor
P08
(%X) 0.00 to 50.00
0.01
%
Y
Y1
Y2
Rated value
of Fuji
standard
motor
P09
(Slip compensation gain for driving) 0.0 to 200.0
0.01
%
Y*
Y
100.0
5-52
P10
(Slip compensation response time) 0.00 to 10.00
0.01
s
Y
Y1
Y2
0.50
P11
(Slip compensation gain for braking) 0.0 to 200.0
0.01
%
Y*
Y
100.0
P12
(Rated slip frequency) 0.00 to 15.00
0.01
Hz
N
Y1
Y2
Rated value
of Fuji
standard
motor
5-51
P99
Motor 1 Selection
0:
-
-
N
0
5-52
1: Motor characteristics 1 (HP rating motors)
3:
4: Other motors
Motor 1 (No. of poles)
Y1
Y2
Name
Motor characteristics 0 (Fuji standard motors, 8-series)
Motor characteristics 3 (Fuji standard motors, 6-series)
Data setting range
Enable (T une %R1 and %X while the motor is stopped.)
Enable (T une %R1, %X and rated slip while the motor is stopped, and
no-load current while running.)
0.01 to 30.00 (where, P99 data is 0, 3, or 4.)
0.01 to 30.00 (where, P99 data is 1.)
The shaded function codes ( ) are applicable to the quick setup.
*
1
When you make settings from the keypad, the incremental unit is restricted by the number of digits that the LED monitor can
display.
(Example) If the setting range is from -200.00 to 200.00, the incremental unit is:
"1" for -200 to -100, "0.1" for -99.9 to -10.0 and for 100.0 to 200.0, and "0.01" for -9.99 to -0.01 and for 0.00 to 99.99.