![FE FRENIC-Multi series Скачать руководство пользователя страница 140](http://html1.mh-extra.com/html/fe/frenic-multi-series/frenic-multi-series_instruction-manual_3750705140.webp)
5-65
Conversio
)
n table (Decimal to/from binary
Binary Binary
Decimal
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Decimal
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0 0 0 0 0 0 16 1 0 0 0 0
1 0 0 0 0 1 17 1 0 0 0 1
2 0 0 0 1 0 18 1 0 0 1 0
3 0 0 0 1 1 19
0 0 1 1
1
4
0 0
0
0 1 0 0 20 1 0 1
5 0 0 1 0 1 21 1 0 1 0 1
6 0
1 0 1 1 0
0 1 1 0 22
7 0 0 1 1 1 23 1 0 1 1 1
8 0 1 0 0 0 24 1 1 0 0 0
9 0 1 0 0 1 25 1 1 0 0 1
10
0 26 1 1 0 1 0
0 1 0 1
11 0 1 0 1 1 27 1 1 0 1 1
12 0 1 1 0 0 28 1 1 1 0 0
13 0 1 1 0 1 29 1 1 1 0 1
14 0 1 1 1 0 30 1 1 1 1 0
15 0 1 1 1 1 31 1 1 1 1 1
J63 to J67
n condition and Timer)
Overload Stop
(Detection value, Detection level, Mode selection, Operatio
When the monitored status index of the load exceeds the detection level specified by J64 for
e period
ates the overload stop function according to
J63 spec
Data for
ection value
Description
th
specified by J67, the inverter activ
operation specified by J65. Use this function for such as system protection from applying a
load that cannot be allowed by the system characteristics or any reason on the system design
or system in which the motor spindle is locked by a mechanical stopper.
Detection value (J63)
ifies the detection value of status index to be monitored.
J63
Det
0 Output
torque
This setting covers the driving torque only.
To improve the accuracy of torque c
auto-tune the inverter for the ap
alculation, be sure to
plied motor.
1 Output
current
The no-load current to the motor always flows. Specify J64
(Detection level) correctly considering the no-load current of
tor.
the applied mo
Detection level (J64)
J64 specifies the detection level putting the rated torque and current of the motor as 100%.