ALARM
CODE
POSSIBLE
CAUSES
CORRECTIVE
ACTION
03
Jacket
Warmup
Slow
Jacket
manual
vent
valve
open
Low
ambient
temperatures
Heater
element
failure
Scale
buildup
on
heater
elements
and
jacket
Close
jacket
vent
valve.
Warm
up
ambient
conditions
to
40°F,
if
possible.
Contact
a
qualified
maintenance
technician
to
inspect
and
replace
heater
element.
Contact
a
qualified
maintenance
technician
to
inspect
heaters
and
jacket
walls
and
clean
as
needed.
Ensure
SWS
is
being
used
on
every
water
refill.
04
Long
Heatup
Steam
leak
Faulty
steam
trap
Resistance
Temperature
Detector
(RTD)
or
RTD
transmitter
failure
Multiple
Heater
element
failure
Inspect
door
gasket
and
chamber
fittings
for
steam
leaks.
Ensure
trap
is
working
properly.
If
steam
trap
is
failed
closed,
condensate
will
pool
in
chamber.
If
steam
trap
fails
open,
steam
will
flow
to
the
WRS
water
tank
and
make
a
loud
popping
noise
or
use
more
water
than
normal.
Replace
as
needed.
Contact
a
qualified
maintenance
technician
to
inspect
RTD
and
RTD
transmitter
for
physical
damage,
loose
wires,
broken
communication
cable
to
PLC.
Compare
temperature
versus
pressure
on
STATUS
SCREEN.
Replace
as
needed.
Contact
a
qualified
maintenance
technician
to
remove
heater
elements,
inspect/test,
and
replace
as
needed.
61
Содержание P2131
Страница 121: ... THIS PAGE INTENTIONALLY LEFT BLANK 115 ...
Страница 130: ...SECTION A APPENDIX 124 ...
Страница 131: ...A 1 Swagelok Fitting Installation Instructions 125 ...
Страница 135: ...A 2 PLC Data Sheet 129 ...
Страница 141: ...A 3 VERIFY Product Information 135 ...
Страница 147: ...A 4 WRS Pump Information 141 ...
Страница 158: ...A 5 Vacuum Leak Test Troubleshooting Guide 152 ...