38
6 Controls and displays, operating modes
The active sensor's actual value (5) and nominal values (7) are shown with prefixes, the
nominal value additionally with a physical unit of measurement (8).
The prefix indicates whether this involves a positive or a negative numerical value.
Only the negative prefix, i.e. " - " appears on the display!
The lateral slope direction arrows only appear if the digital slope sensor has been selected
as the active sensor. The slope direction of the displayed arrow is the prefix for the digital
slope sensor value (left slope or right slope). Both arrows only appear simultaneously
together with the display "0.0%".
The resolution and the physical unit of measurement for the displayed values can be set in
the configuration menu - separately for distance sensors and slope sensors.
Содержание Dynapac SCREED-CONTROL
Страница 2: ...www dynapac com ...
Страница 62: ...62 8 Operation in general The new sensor is ready to operate 6 2 4 0 2 4 0 2 4 0 ...
Страница 166: ...www dynapac com ...