14 Help in the event of malfunctions
CAN-ERR
Cause: The connection between the Screed Controller and the higher-
level control system is interrupted.
Control outputs: No further control signals whatsoever can be
transmitted to the tractor.
Remedy: CAN connection must be restored, as continuing to work is
otherwise impossible.
Contact the manufacturer;
Cause: An error has occurred in the CAN network;
Control outputs: The outputs are locked in automatic mode;
Remedy: Check all system connection cables for damage;
Contact the manufacturer;
Cause: Data loss has occurred in the memory;
Control outputs: The outputs are locked in automatic mode;
Remedy: Acknowledge the error message with any button and reset the
working point and nominal value;
Contact the manufacturer if this occurs repeatedly;
Cause: The temperature in the interior of the remote control
approaches the permissible maximum temperature;
Consequence: The device continues to heat up, but switches off
automatically on reaching the permissible maximum temperature;
Remedy: Acknowledge the error message with any button - the remote
control initially continues to operate as normal;
Prevent further heating (shading, cooling, different installation location,
etc.);
Cause: The temperature in the interior of the remote control
approaches the permissible minimum temperature;
Consequence: The device continues to cool down, but switches off
automatically on reaching the permissible minimum temperature; the
display backlighting remains on as a heat source
1)
;
Remedy: Acknowledge the error message with any button - the remote
control initially continues to operate as normal;
Protect the remote control against further cooling;
1)
Note: If the remote control is commissioned at a temperature below the specified
operating temperature (also refer to the technical data in this regard), all of the device's
LEDs flash. The display backlighting is activated and serves as a source of heat until the
display can be activated without risk.