9 Levelling system operation
129
9.12.1 Installation and set-up
The digital slope sensor is mounted between the traction arms on the
crossbeam slightly downstream of the screed.
(for further installation details please also refer to chapter "9.1.1
Installation and set-up")
9.12.2 Actual value reset
The actual value reset synchronises the measured value of the digital
slope sensor with the actual slope of the tool.
This synchronisation is necessary for example if the digital slope sensor
has not been installed absolutely parallel to the lower edge of the tool.
(see also chapter "9.1.2 Actual value reset")
9.12.3 Controlling with the travel-dependent digital slope sensor
Press F1 (
) to call up the sensor selection menu.
If the normal slope control was active before (as shown on
the right), selecting the delta slope sensor does not
deactivate the slope control.
Select the delta slope sensor using the up/down buttons.
If more sensors are connected than fit in the display, the
system automatically scrolls forwards.
The selection has a black background.
Confirm the selection with the enter button.
%
1. 00
1. 00
6
Содержание Dynapac SCREED-CONTROL