6 Controls and displays, operating modes
47
6.5 Levelling system operating variants
In the basic configuration set by the manufacturer, operation of the remote control can be
set to three different variants. This operation then differs as follows:
6.5.1 Standard operation
In
"automatic"
operating mode, nominal value adjustment using the up/down buttons is
carried out in
1 mm
steps as long as the relevant button remains depressed.
In this case, the screed is moved by the control system as specified.
The changed nominal value is shown on the display.
By simultaneously pressing the enter button together with the up button or the down button,
the displayed nominal value can be changed without influencing the position of the screed.
6.5.2 Operation with semi-automatic
In
"semi-automatic"
and
"automatic"
operating modes, nominal value adjustment using
the up/down buttons is carried out continuously in
1 mm
steps as long as the relevant button
remains pressed.
In
"semi-automatic"
operating mode, the screed is not initially actuated, as the outputs are
locked in this operating mode.
If the system is switched from "semi-automatic" operating mode to
"automatic"
operating
mode, the outputs are released and the screed is moved by the control system as specified.
The changed nominal value is shown on the display in both operating modes.
By simultaneously pressing the enter button together with the up button or the down button,
the displayed nominal value can be changed without influencing the position of the screed.
Switching between the "manual", "semi-automatic" and "automatic" operating modes is
carried out in sequence using the auto/manual button.