9 Levelling system operation
101
9.3.3 Controlling with the Sonic-Ski
®
plus in cable sensing
1) Use the auto/manual
button to switch the
controller to "manual"
operating mode.
2) Select
Sonic-Ski
®
plus
sensor
in cable sensing
as
described.
The sensor symbol and
the symbol for "manual"
are shown on the
display.
6
3) Move the screed to the
working position for
calibration to zero using the
up/down buttons or the
toggle switch on the remote
control.
4) Align the sensor above
the reference as described
in the section entitled
"Installation and set-up".
5a) Press the enter button.
The nominal value has a
black background and the
current actual value is
taken over as the nominal
value.
5b) Keep the enter button
pressed for approx.
2 seconds.
The actual value and the
nominal value initially
have a black
background.
The actual value and the
nominal value are set
to "0.0".
6) Use the auto/manual
button to switch the
controller to "automatic"
operating mode.
The controller maintains
the screed at the set
value.
7) In automatic mode, the
up/down buttons can now be
used to change the nominal
value to enable corrections to
be carried out.
c m
6
0. 0
0.0
c m
9. 8
6
9. 8