9 Levelling system operation
9.3 Working with the Sonic-Ski
®
plus
9.3.1 Installation and set-up
Installation
direction for
ground sensing
For ground sensing, the Sonic-Ski
®
plus must be operated
longitudinally to the vehicle's direction of travel (mean value formation).
Installation
direction for
cable sensing
For cable sensing, the Sonic-Ski
®
plus must be operated transversely
to the vehicle's direction of travel. Align the sensor centrally above the
cable.
So that the cable is shown for the correct side beneath the Sonic-Ski
®
plus sensor heads, the sensor must be mounted on both sides as
shown in the sensor symbol; i.e. with the connector pointing to the left
in each case (viewed in the direction of travel).
The cable is only clearly recognised as a reference as of a diameter of
3 mm.