14 Help in the event of malfunctions
159
Cause: Positive deviation from the laser transmitter's specified
maximum rotational speed (>20 Hz [revolutions per second]);
Control outputs: The outputs are locked in automatic mode;
Remedy: Reduce the laser transmitter's rotational speed if it is
equipped with a speed control;
Remove reflective surfaces (motor vehicle glazing, windows, etc.) from
the laser beam's area of influence or cover these surfaces;
Legend:
= LED is off
= LED flashes
= LED is on