46
6 Controls and displays, operating modes
6.3 Malfunction displays
If all of the LED arrow's LEDs flash simultaneously on the
remote control, a malfunction is present.
Often, these malfunctions do not involve genuine defects but
indicate an attempt to operate the vehicle under
impermissible conditions.
Information on malfunction rectification can be found in the
description of work with the various sensors and in the
section entitled "Help in the event of malfunctions".
= LED flashes
6.4 Levelling system operating modes
Manual mode
In "manual" operating mode, the screed is moved directly using the up/down
buttons on the remote control.
Automatic
In "automatic " operating mode, the nominal value for the relevant control circuit
is changed using the up/down buttons on the remote control.
If comparison of the measured actual value and the set nominal value results in
a difference, the remote control independently actuates the outputs until this
difference has been compensated.
Flashes
Semi-automatic
1
In "semi-automatic " operating mode, the nominal value for the relevant control
circuit can be changed using the up/down buttons on the remote control.
However, the screed is not actuated, as the outputs are locked in this operating
mode.
Locked
In "locked" operating mode, the higher-level control system has locked all control
circuits.
1
This operating mode occurs when the higher-level control system has deactivated regulation,
e.g. when the vehicle is stationary, or if the optional operating variant with semi-automatic mode
has been activated in the parameter menu (also see next page).