14 Help in the event of malfunctions
157
General:
Cause: The connection to the active sensor has suddenly been lost
during operation;
Control outputs: The outputs are locked in automatic mode;
Remedy: Check the sensor's connection cable for damage
and
exchange it if necessary;
Exchange the sensor;
Cause: The active sensor transmits impermissible or contradictory
messages or measured values;
Control outputs: The outputs are locked in automatic mode;
Remedy: Unplug the sensor, realign it via the reference and
reconnect it;
Exchange the sensor if necessary;
Specifically when working with the power mast:
Cause: The power mast is equipped with its own internal measuring -
system, with which it can determine how far it is currently extended at
any time;
In exceptional situations, the mast may "forget" this current position;
Control outputs: The outputs are locked in automatic mode;
Remedy: Retract the power mast completely once so that it can
automatically re-initialise itself in this position;
Cause: Although one of the remote control's outputs is actuated, no
current flows to or in the power mast;
Control outputs: The outputs are locked in automatic mode;
Remedy: Check the power mast's connection cable for damage
and
exchange it if necessary;
Exchange the power mast;
Содержание Dynapac SCREED-CONTROL