9 Levelling system operation
113
9.7.3 Controlling with the prop. laser receiver
1) Use the auto/manual
button to switch the
controller to "manual"
operating mode.
2) Select the
laser receiver
as described.
The sensor symbol and
the symbol for "manual"
are shown on the
display.
6
3) Move the screed to the
working position for
calibration to zero using the
up/down buttons or the
toggle switch on the remote
control.
4) Align the laser receiver
centrally with the reference
as described in the section
entitled "Installation and set-
up".
5a) Press the enter button.
The nominal value has a
black background and
the current actual value
is taken over as the
nominal value.
5b) Keep the enter button
pressed for approx.
2 seconds.
The actual value and the
nominal value initially
have a black
background.
The actual value and the
nominal value are set
to "0.0".
6) Use the auto/manual
button to switch the
controller to "automatic"
operating mode.
The controller maintains
the screed at the set
value.
7) In automatic mode, the
up/down buttons can now
be used to change the
nominal value to enable
corrections to be carried
out.
c m
6
0. 0
0. 0
c m
9. 8
6
9. 8
Содержание Dynapac SCREED-CONTROL
Страница 2: ...www dynapac com ...
Страница 62: ...62 8 Operation in general The new sensor is ready to operate 6 2 4 0 2 4 0 2 4 0 ...
Страница 166: ...www dynapac com ...