14 Help in the event of malfunctions
151
14.2 Troubleshooting and malfunction rectification
Warning
messages
Warning messages appear in the operating window at the position of
the currently active sensor's actual value.
OUT
In the case of sensor combinations (Big Sonic-Ski
®
, power mast with
laser receiver, etc.) a separate warning message is shown for each
individual component.
If "automatic" operating mode was active at the time at which a warning
message occurred:
"Automatic" operating mode remains active
The valve outputs are switched off
The entire LED arrow flashes
If the cause of the malfunction disappears independently (insect in the
measuring range of an ultrasonic sensor, vehicle drives over a pin,
etc.), the remote control immediately continues to operate without the
operator having to intervene.
If the malfunction remains, the cause must be investigated and
rectified.