14
Revision date: 12.02.16
SETTING THE MOUNTING FEET
For those buildings equipped with mounting feet, secure the feet to either a concrete foundation or concrete piers prior to attaching
the rafter legs and assembling the frame.
Customer is responsible for laying the necessary concrete foundation or
concrete piers. Consult and follow local and regional building codes for slab requirements.
Once concrete has cured, attach 115249/115250 base plates. Ensure base plates are aligned and spaced according
to technical documents at the end of these instructions. Attach using the appropriate mounting hardware (purchased
separately).
ATTENTION:
Consult a qualified construction contractor familiar with anchor bolt requirements and installation using
epoxy. If building frame includes ground posts, you must enlist the services of a qualified, professional contractor
familiar with the layout and setting of ground posts in concrete.
Plates must be aligned, plumb, and set at correct,
uniform height for building to assemble properly.
Diagram not to scale.
General Anchor Bolt and Epoxy Installation
Steps:
1. Determine on-center position of base
plate. Mark center of plate and mark on-
center position of plate on foundation.
Consult layout in technical documents.
2. Square plate on foundation, align marks,
and mark bolt hole locations using base
as a template.
3. Remove base plate and drill mounting holes according to requirements of anchor bolts.
4. Clean bolt holes according to anchor bolt specifications and the directions on epoxy container.
5. Once holes are clean, set plate back in place and apply recommended epoxy into each hole as described by
epoxy manufacturer.
6. Take anchor bolts (with nuts and washers installed) and carefully insert one into each bolt hole. Adjust nut and
washer on anchor bolt to gauge how far bolt will drop into hole.
7. Allow epoxy to set according to manufacturer's instructions before tightening.
8. Repeat procedure to install remainder of base plates.
9. After epoxy has set, return to all anchor bolts and tighten according to manufacturer's instructions.
Mounting Foot Installation
6' On-Center
Concrete
Concrete
Align Marks
Align Marks
115249
Corner
Base Plate
115250
Mid
Base Plate
Drawing may show layout of a
different length. Refer to technical
documents located in the back of
these instructions for on-center
measurements and plate layout for
your frame.