Shenzhen Hpmont Technology Co., Ltd.
Chapter 6 Function Introduction
MONT72 Series User Manual V1.0
- 55 -
6.2.7
F06: Weighing Compensation Parameters
Ref. Code
Function Description
Setting Range [Default]
F06.00
Pre-torque selection
0 - 2 [0]
The pre-torque function can output the load balancing torque in advance to avoid reverse and reduce the
start impact.
0: No pre-torque function.
1: No weighing auto-compensation.
•
This mode is available for all types of encoders.
2: Asyn. motor zero-serve auto-compensation.
F06.01
No weighing current coefficient
0 - 9999 [3000]
F06.02
No weighing speed-loop KP
1 - 9999 [500]
F06.03
No weighing speed-loop KI
1 - 9999 [500]
F06.01 - F06.03 are used to adjust the effect of no weighing auto-compensation (F06.00 = 1).
•
The system response can be expedited through increasing F06.01 - F06.03, but system oscillation and
overshoot may occur if the value of F06.01 - F06.03 is too high.
•
Generally, it can smoothly start elevator via adjusting F06.01 when debugging.
•
Increase F06.01 to avoid sliding vehicle at starting moment. Decrease F06.01 to avoid shake at starting
moment.
6.2.8
F07: Asyn. Motor Parameters
F06.00 = 0
F06.00 = 1
F06.00 = 2
No weight
auto-compensation
Speed command
Speed feedback
Counter
weight
No weight adjust
(F06.01
-
F06.03)
ASR
Torque
limit
ACR
+
-
+
+
M
Car
L
m
R1=F07.07 (Stator resistance)
R2=F07.08 (Rotor resistance)
Io=F07.11 (Excitation current)
R1
R2
LI
I1
I2
S
1-S
R2
LI
LI=F07.09 (Leakage inductance)
Lm=F07.10 (Mutual inductance)
S=Slip ratio
U1
Io
6
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......