Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd.
- 92 -
MONT72 Series User Manual V1.0
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
Bit9 - Bit0 corresponds to X10 -
X1
D02.04
Output terminal status
A 16-bit binary number, from
high to low, is:
Bit5 - Bit2 corresponds to Y4 - Y1
Bit1 - Bit0 corresponds to DO2 -
DO1
Actual value
*
D02.05
Elevator running state
A 16-bit binary number:
Bit0: Driver enable
Bit1: Inspection running
Bit2: Multi-speed
Bit3: Analog running
Bit4: Brake feedback input
Bit5: Contactor feedback input
Bit6: Multi-speed terminal 1
Bit7: Multi-speed terminal 2
Bit8: Multi-speed terminal 3
Bit9: Emergency running
Bit10: Brake output
Bit11: Running contactor
Bit12: Running direction
Bit14 & Bit13: Control mode
Bit15: Reserved
Actual value
*
D02.06
Driver status
A 16-bit binary number:
Bit0: Controller fault
Bit1: Running / stop
Bit2: Up running
Bit3: Down running
Bit4 & Bit5: Acc./ Dec. / constant
speed
Bit6: Zero-speed signal
Bit7: Zero-speed running
Bit8: Parameter auto-tuning
Bit9: Speed arrival
Bit10: Running is ready
Bit11: Brake output
Bit12: Contactor output
Bit13: Stop signal
Bit14, Bit15: Reserved
Actual value
*
D03: Running Status Parameters (see page 48 - 48)
D03.00
Current fault
Actual value
*
D03.01
Current fault sub-code
0 - 100
Actual value
*
D03.02
Acculated power-on time
0 - 65535hours
Actual value
*
D03.03
Acculated running time
0 - 65535hours
Actual value
*
D03.04
High bit of running times
0 - 65535
Actual value
*
D03.05
Running times
0 - 65535
Actual value
*
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......