Ref. Code
Function Description
Setting Range [Default]
F05.10
Speed detection level 1 (FDT1)
0.0 - 100.0 (F00.02) [90.0%]
F05.11
Speed detection level 2 (FDT2)
0.0 - 100.0 (F00.02) [90.0%]
F05.12
Speed detection hysteresis level FDT1
0.0 - 100.0 (F00.02) [1.0%]
F05.13
Speed detection hysteresis level FDT2
0.0 - 100.0 (F00.02) [1.0%]
When the running speed is lower than a certain speed
(F05.10 + F05.12), as shown in the figure FL, the ON
indication signal is output until the running speed is
less than F05.10.
•
For F05.11, F05.13 see parameters F05.10, F05.12.
F05.14
Speed within FAR range
0.0 - 20.0 (F00.02) [1.0%]
The pulse signal will output if elevator speed is
within the FAR range. As shown in the right figure.
F05.15
Over-speed setting
80.0 - 120.0 (F00.02) [115.0%]
F05.16
Over-speed detection time
0.0 - 2.0 [0.2s]
When the actual elevator speed exceeds F05.15 and the duration time exceeds F05.16, MONT72 alarms
E0032 fault (motor over speed).
•
F05.16 = 0, MONT72 does not detect motor over speed fault.
F05.17
Detected value of speed deviation
0.0 - 30.0 (F00.02) [20.0%]
F05.18
Detected time of speed deviation
0.0 - 2.0 [1.0s]
When the deviation of setting speed (after Acc. / Dec.) and actual run speed of motor exceeds F05.17 and
the duration time exceeds F05.18, MONT72 alarms E0018 fault (excessive speed deviation).
•
F05.17 or F05.18 = 0, MONT72 does not detect the excessive speed deviation fault of motor.
Elevator speed
F05.12
F05.10
FL
Time
Time
DO
ON
ON
OFF
Elevator speed
Output
Time
Time
Setting speed
DO
F05.14
F05.14
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......