Appendix A Parameters
Shenzhen Hpmont Technology Co., Ltd.
- 94 -
MONT72 Series User Manual V1.0
Ref. Code
Function
Setting Range
Default
Unit
Attribute Setting
F02.02
Retention time of start
zero-speed
0.000 - 4.999s
0.500s
0.001s
×
F02.03
Start speed
0.000 - 0.400m/s
0.000m/s
0.001m/s
×
F02.04
Retention time of start
speed
0.000 - 4.999s
0.000s
0.001s
×
F02.05
Brake close delay time
0.000 - 4.999s
0.200s
0.001s
×
F02.06
Retention time of stop
zero-speed
0.000 - 4.999s
0.300s
0.001s
×
F02.07
Contac tor close delay time
0.000 - 4.999s
0.000s
0.001s
×
F02.08
Start ramp time
0.000 - 2.000s
0.000: No ramp
0.000s
0.001s
×
F03: Acc. / Dec. Parameters (see page 52 - 53)
F03.00
Acc. speed
0.020 - 9.999m/s
2
0.700m/s
2
0.001m/s
2
×
F03.01
Start Acc. jerk
0.020 - 9.999m/s
3
0.350m/s
3
0.001m/s
3
×
F03.02
End Acc. jerk
0.020 - 9.999m/s
3
0.600m/s
3
0.001m/s
3
×
F03.03
Dec. speed
0.020 - 9.999m/s
2
0.700m/s
2
0.001m/s
2
×
F03.04
Start Dec. jerk
0.020 - 9.999m/s
3
0.600m/s
3
0.001m/s
3
×
F03.05
End Dec. jerk
0.020 - 9.999m/s
3
0.350m/s
3
0.001m/s
3
×
F03.06
Inspection Acc. speed
0.020 - 9.999m/s
2
0.200m/s
2
0.001m/s
2
×
F03.07
Inspection Dec. speed
0.020 - 9.999m/s
2
1.000m/s
2
0.001m/s
2
×
F03.08
Battery driven Acc. speed
0.020 - 9.999m/s
2
1.000m/s
2
0.001m/s
2
×
F03.09
Battery driven Dec. speed
0.020 - 9.999m/s
2
1.000m/s
2
0.001m/s
2
×
F03.10
Auto-tuning Acc. speed
0.020 - 9.999m/s
2
0.100m/s
2
0.001m/s
2
×
F03.11
Auto-tuning Dec. speed
0.020 - 9.999m/s
2
0.100m/s
2
0.001m/s
2
×
F03.12
Abnormal Dec. speed
0.020 - 9.999m/s
2
1.000m/s
2
0.001m/s
2
×
F03.13
Stop Dec. jerk
0.020 - 9.999m/s
3
0.350m/s
3
0.001m/s
3
×
F03.14
Asyn. motor field-weakening
optimization
0: No field-weakening
optimization
1: Optimize according to voltage
2: Optimize according to current
0
1
×
F03.15
Field-weakening Kp
0 - 5000
4000
1
×
F03.16
Field-weakening Ki
0 - 5000
1000
1
×
F03.17
Field-weakening voltage
limit
4000 - 5000
4126
1
×
F03.19
Sincos encoder CD phase
learning
0: Learning
1: Not learning
0
1
×
F04: Analogue Curve Parameters (see page 53 - 53)
F04.00
Setting curve
Unit: AI1 characteristic curve
selection
Ten / Hundred / Thousand:
Reserved
0: Line 1
1: Line 2
0000
1
×
F04.01
Line 1 min. setting
0.0% - F04.03
0.0%
0.1%
○
Содержание MONT72 Series
Страница 1: ...V1 0 2018 09 MONT72 Series Elevator Controller User Manual MONT72 Series Elevator Controller ...
Страница 3: ...Version and Revision Records Version time 2018 9 Version V1 0 Chapter Content V1 0 issue ...
Страница 7: ......
Страница 9: ......
Страница 15: ......
Страница 43: ......
Страница 81: ......
Страница 99: ......