2.7
Tool calibration
Tool calibration is available in the jog mode. The softkey to access tool calibration will be
different depending on the software installed (lathe model or mill model). To quit the
calibration mode and return to jog mode, press the [ESC] key.
The CNC offers in both models the possibility to calibrate lathe tools and milling tools. The
CNC will show the necessary data and will update the help graphics according to the selected
tool.
Types of calibration
There are several ways to calibrate a tool. Some ways are only available when using a table-
top probe.
The active kinematics are taken into account and do not prevent tool calibration in this mode.
Manual or semi-automatic calibration will not be possible if a coordinate ( #CS or #ACS)
transformation is active or when either the RTCP or TLC function is active.
Manual calibration. Calibration without a probe.
It is done without the table-top probe. A reference part is required to calibrate the tool. All
the movements are carried out manually.
Semi-automatic calibration. Calibration with a probe.
This calibration mode is available when using a table-top probe. The positioning movements
are carried out manually and the CNC executes the probing movements.
Automatic calibration. Calibration with a probe and a canned cycle.
This calibration mode is available when using a table-top probe. The CNC executes all the
movements using the calibration canned cycle #PROBE.
Probe selection
Two probes may be configured at the CNC. The probe active at the time is used for
calibration. The active probe may be changed via part-program or MDI using the instruction
#SELECT PROBE.
Tool calibration in a mill model.
Only manual calibration is possible when not using a table-top probe.
All types of calibration are available when using a table-top probe. The
different calibration methods may be selected from the vertical softkey
menu.
#SELECT PROBE [1]
Selects the first probe.
#SELECT PROBE [2]
Selects the second probe.
Содержание CNC 8060
Страница 1: ...Ref 1709 8060 8065 CNC Operating manual MC...
Страница 8: ...BLANK PAGE 8...
Страница 14: ...BLANK PAGE 14...
Страница 16: ...BLANK PAGE 16...
Страница 18: ...BLANK PAGE 18...
Страница 22: ...BLANK PAGE 22...
Страница 24: ...BLANK PAGE 24...
Страница 26: ...BLANK PAGE 26...
Страница 28: ...Operating manual MC CNC 8060 CNC 8065 1 GENERAL CONCEPTS Accessing the conversational mode 28 REF 1709...
Страница 169: ...Operating manual MC CNC 8060 CNC 8065 169 User notes REF 1709...
Страница 170: ...Operating manual MC CNC 8060 CNC 8065 170 User notes REF 1709...
Страница 171: ...Operating manual MC CNC 8060 CNC 8065 171 User notes REF 1709...