Table 12.
Decoder Alarm Type and Description
Alarm Type
Description
Action
Default Settings
Decoder Alarm
No
decoder
video
data
Indicates that there is a valid
connection, no video data present.
Usually accompanied by no source
data stream message in the web
interface.
Warning, reporting
No
decoder
mode
No matching decoder mode for the
incoming stream.
Warning, reporting
No
source
report
Unable to detect the format of the
received data stream.
Warning, reporting
Recovered
audio
Not applicable to VNC 325.
N/A
No
decoder
audio
data
Not applicable to VNC 325.
N/A
Bad
audio
at
decoder
Not applicable to VNC 325.
N/A
Bad
audio
PLL
Not applicable to VNC 325.
N/A
Video
network
packets
dropped
Excessive network packet loss has
occurred.
Warning, reporting
Decoder
buffer
overflow
The incoming data rate is high;
reduce the pipeline delay.
Warning, reporting
Decoder
buffer
underflow
The incoming data rate is too low;
increase the pipeline delay.
Warning, reporting
Bad
video
PLL
The decoder cannot synchronize to
the video data.
Warning, reporting
No
decoder
ANC
data
The decoder is not receiving any
embedded audio (ancillary) data.
Warning, reporting
Missing
ANC
at
decoder
The decoder is receiving poor quality
Anc data.
Warning, reporting
Recovered
ANC
Error correction has recovered
corrupted / missing Anc.
Warning, reporting
Table 13.
Controller Alarm Type and Description
Alarm Type
Description
Action
Default Settings
Contr
oller Alarm
Bad
device
The controller is unable to contact
the specified device. The device is
not available or has failed.
Check the device in
question:
•
Has the unit been
removed?
•
Is power applied?
•
Are the network
cable and
connection
present?
Critical, reporting
VN-Matrix 325 Serial Digital Over IP CODEC • Alarms and SNMP