NOTES:
�
The
activate
and
commit
stages reboot the controller. This results in two
considerations:
•
The upgrade file in the temporary storage area of the controller codec is
erased. Extron recommends that you:
•
Prepare
all devices first (the upgrade page displays the
READYTOACTIVATE
message.
•
Then
activate
the upgrade on each device (the upgrade page displays
the
READYTOCOMMIT
message), starting with the controller VNC 325.
If you inadvertently
activate
the upgrade in the controller codec before all
devices are prepared,
upload
the file again (see below).
•
There is a temporary loss of the network interface. Wait 30 seconds to
allow the VNC 325 to reboot, then refresh the browser.
�
Perform the
activate
stage on the controller codec first to ensure that the new
firmware controls the upgrade of the remaining devices. Extron recommends
that you
activate
all devices (the upgrade page displays the
READYTOCOMMIT
message) before
committing
to the controller upgrade.
Uploading the upgrade to the controller codec
Upload the file to a temporary storage area on the controller VNC 325 in accordance with
the procedure below. From this location, it can be installed on all codecs in the system.
1.
Login to the network interface (see “
Startup and Login
“ in the “Installation and
Setup” section).
2.
On the device list page, click anywhere on the row (except the Delete column) for the
controlling VNC 325 to select that codec to receive the firmware upload (
a
on figure
43
).
1
2
3
Device List
Page
Device
Page
Upgrade
Page
Figure 43.
Upgrade Page
3.
On the device page, click the
Upgrade
tab (
b
). The upgrade page appears (
c
). The
page includes the following drop-down box and data fields:
•
Select Firmware Version drop-down box
— Selects the version to be used.
•
Committed Version field
— Displays the currently loaded and running version.
•
Upgrade Version field
— Displays the version to which you are upgrading.
•
Device Upgrade Status
— Reports the status of the upgrade process. At this point
in the upload procedure, it reports
WAIT
.
VN-Matrix 325 Serial Digital Over IP CODEC • Operation