Configuring a Serial Pass-through Group
NOTE:
The client and server ends of the serial pass-through connection do not have
to have the same baud rate settings, however having the different ends at
vastly different rates can result in unexpected results.
1.
Decide which device is to be the server.
2.
On the device list page (see
figure 23
on page 32), click on the device you want to
configure.
3.
On the device page (see
figure 25
on page 34), click the
peripherals
tab.
4.
On the peripherals page (see
a
on figure
41
), set the mode to either
server
or
client
.
If you select client, the destination drop-down box (
c
) appears.
1
Configuring the Server
Configuring a Client
1
4
4
2
2
2
2
2
2
2
2
2
2
3
Figure 41.
Configuring a Serial Pass-through Group
5.
Configure the baud rate, data bits, stop bits, parity, and handshake settings as required
(
b
).
6.
In the destination drop-down box, select
passthrough
for the appropriate server (
c
).
7.
Click the
update
button (
d
).
8.
Repeat steps
2
through
7
for all
9.
Click the
Save
All
tab to save the changes.
NOTE:
If you do not click
Save
All
, the settings are lost when power is cycled on
and off.