![Extron electronics SMD 101 Скачать руководство пользователя страница 92](http://html1.mh-extra.com/html/extron-electronics/smd-101/smd-101_user-manual_2456436092.webp)
Reset Device
Provides several options to reset the SMD 101 if hardware or software conditions require.
See the
on page 136 for a comparison of the reset modes.
NOTE:
Proceed with caution. Some reset modes intentionally delete all user files,
media content, and settings from internal memory.
Figure 79.
Device Reset, Reset Options
To reset the device:
1.
Click the
Advanced
Configuration>Reset
Device
icon on the navigation bar (see
The
Reset
Device
page opens (see figure 79).
2.
Click the radio button for the desired reset option.
1
Reset Device settings to default, but retain user files and all IP settings
—
Resets all hardware and software to default condition, but retains user files and IP
settings for communication.
2
Reset Device settings and delete internal user files (Retains all IP
settings)
— Resets all hardware and software to default condition, deletes user
files stored in internal memory, and retains communication settings including the IP
address, subnet mask, gateway IP address, device name, DHCP setting, and port
mapping. This reset is recommended after updating device firmware.
3
Reset Device settings, delete internal user files, and reset all IP settings
—
Resets all hardware and software to default condition including the communications
settings.
NOTE:
If the control PC is connected via the Ethernet port, communications
is broken. Use the default IP address (
192.168.254.254
), subnet mask
(
255.255.0.0
), and default gateway (
0.0.0.0
), the front panel config port, or the
rear panel RS-232 port to reconnect.
3.
Click
Apply
(
5
). The reset process begins.
4.
Depending on the reset option chosen, either refresh the browser page to reconnect to
the SMD 101 or enter the default IP address into the browser.
Reboot Now
If conditions exist that cause to the device to stop responding to other software commands
or to front panel button presses, click
Reboot
Now
(
4
) to force a reboot. The reboot
process is unrelated to the reset options and no changes are made to settings or files on
the unit.