![Extron electronics SMD 101 Скачать руководство пользователя страница 75](http://html1.mh-extra.com/html/extron-electronics/smd-101/smd-101_user-manual_2456436075.webp)
NOTE:
By default the host or device name is a combination of the model name
(SMD 101) and the last half of the MAC address for that unit. It can be changed to
any alphanumeric name of up to 63 characters. Letters, numbers, and hyphens
are allowed. Spaces and symbols are not permitted. The name must start with a
letter. A hyphen cannot be used for the first or last character.
•
Link Local:
— An IP address automatically negotiated by the SMD 101 when not
assigned a static IP address and DHCP is disabled, or when DHCP is enabled but a
DHCP server is not found.
•
MAC Address:
— The MAC address of the connected SMD 101. The address is also
available on the rear panel label.
•
Reset to Default:
— Resets all network configuration to default.
•
Save
— Saves manual network configuration changes.
•
Cancel
— Discards manual network configuration changes.
NOTES:
•
The DHCP assigned Gateway and DNS address are retained after DHCP is
deselected. They are reset using the reset button on the rear panel (see
on page 13) or using the web-based user interface (see
•
The network interface restarts when changes are saved.
To set a static IP address:
1.
Click the
Advanced
Configuration
tab above the navigation bar (see
2.
Click the
Connection
icon on the navigation bar.
The
Connection Settings
3.
Enter an IP address for the device in the
IP
Address
field in the
Ethernet
Settings
panel (
1
).
4.
Enter the subnet mask for the device in the
Subnet
Mask
field.
5.
Enter the default gateway in the
Default
Gateway
field.
6.
Enter the IP address of the Domain Name System (DNS) server in the
DNS
Server
field.
7.
If desired, specify the unit name of this SMD 101 device in the
Host
Name
field. The
default name is a combination of the model name and the last six digits of the MAC
address. After it is saved, this name also appears in the
Device Information
page.
The name can be changed on either page.
NOTE:
By default the host or device name is a combination of the model name
(SMD 101) and the last half of the MAC address for that unit. It can be changed to
any alphanumeric name of up to 63 characters. Letters, numbers, and hyphens
are allowed. Spaces and symbols are not permitted. The name must start with a
letter. A hyphen cannot be used for the first or last character.
8.
Click
Save
to save the settings or click
Cancel
to discard changes.
To use Dynamic Host Control Protocol (DHCP) to obtain an IP address automatically for the
device:
SMD 101 • Web-based User Interface
68
Содержание SMD 101
Страница 2: ......