To specify the source to play upon boot up, from the browser or favorites panel:
1.
Right-click the desired source
2.
From the context list, select
Set
as
Boot
Play
.
The selected source now plays when the SMD 101 is powered on.
If the desired source is not available locally:
1.
Click
Configuration>Automation
.
2.
The
Automation
page opens (see
3.
In the
Boot Play
panel (see figure 60), enter the URL of the source stream or the path
of the folder location for the desired file in the
Source to play on power up:
field.
Figure 60.
Automation Page - Boot Play
4.
Click
Save
. The source address now plays when the SMD 101 is powered on. Click
Cancel
to discard the newly entered source address.
Fail Over
In this panel (see
4
on page 60) you specify the time to wait after a data
stream is interrupted before the SMD switches to an alternative source which can be a
solid color on the screen or any source from a specified source path. The time to wait after
the stream is lost, the solid background color that plays in the event of stream loss, and
an alternate source clip, image, playlist, or stream on the local drive can be selected here.
Settings include :
Display Solid Color
— The length of time after a stream loss before a solid color screen is
output to the connected display. Click the
After
checkbox to activate the fail over mode.
Select the time after the stream loss is detected before the solid screen is output.
Color
— The color of the fail over output. There are three choices:
•
Black
presents a black screen.
•
Blue
with
OSD
bug
displays a blue background with the message:
SMD101:
No
Source
Input
.
•
Custom
allows selection of a solid color background using the drop-down palette or by
entering the hex value of the desired color directly into the field.
NOTE:
The hex value uses HTML formatting with a # prefix (#RRGGBB). For
example, cyan is #00FFFF.
Source from Path Below:
— Select a clip or image to display upon entering fail over
mode. Although not a requirement, the alternative is ideally located on internal or local
removable (such as the SD card) storage, to remove dependence on the network. The
SMD 101 does not automatically revert from the fail over source to the primary source
if it becomes available. External control system monitoring can achieve this operation if
required. Right-click the file and select
Set
as
Failover
Play
or cut and paste the file into
the field. Alternately, click
Source
from
Path
Below:
and type the folder location of the file
SMD 101 • Web-based User Interface
62
Содержание SMD 101
Страница 2: ......