The SNMP panel (see
on page 72) provides the following features:
•
Enable SNMP
— SNMP is disabled by default. Check this box, then click
Save
to enable SNMP. If SNMP is enabled, a strong password (community strings) is
recommended.
•
Unit Contact
— The name of the person to contact with questions on operation or
configuration. To change the contact information, enter the new information in the field,
then click
Save
.
•
Unit Location
— The location of the device. For easier identification on the network,
enter a descriptive name in this field, then click
Save
.
To set up SNMP on the SMD 101:
1.
Click
Advanced
Configuration>Connection
.
The
Connection Settings
2.
In the
SNMP
panel, click the
Enable
SNMP
box (
2
). When checked, the unit allows
SNMP communication. If unchecked (clear), the unit will not use SNMP.
3.
Click
Save
(
¢
) at this time to save the SNMP setting, or proceed to configure additional
items.
NOTE:
Changes to any setting in this page are not applied until you click
Save
.
4.
If desired, in the
Unit
Contact
field (
3
), enter the name of the person who can be
contacted for assistance with this SMD 101 unit in case someone (such as a network
administrator) has questions about the device.
5.
If desired, for easier identification by users viewing device information on the network,
enter a brief descriptive name for the physical location of the SMD 101 in the
Unit
Location
field (
4
). Spaces are permitted in this field.
NOTE:
This location name is the same as the device location that can be set from
the
Device
Information
6.
Click
Save
(
¢
).
Password Management panel
Access to the SNMP page can be public or private. Public access provides read-only
access to all SNMP features. Private access allows both read and write access.
The two passwords must be different to provide security from unwanted changes. If desired,
to set and reset public and private passwords:
1.
Click
Public
(
5
) to set a password for network management that will be publicly
accessible.
2.
Enter a password in the
Public
Password
field (
7
), then enter the same password
in the
Confirm
Password
field (
8
). The password can be any alphanumeric name of
4 to 12 characters. Letters, numbers, and hyphens are allowed. Spaces, slashes, and
symbols are not permitted.
3.
Click
Private
(
6
) to set a password for a more limited group. The
Public
Password
field changes to
Private
Password
.
4.
Enter a password in the
Private
Password
field (
7
), then enter the same password in
the
Confirm
Password
field (
8
).
5.
Click
Save
(
¢
) to save the settings or click
Cancel
(
£
) to discard the changes.
6.
Click
Reset
to
Default
(
9
) to return all settings to their default values.