![Extron electronics SMD 101 Скачать руководство пользователя страница 121](http://html1.mh-extra.com/html/extron-electronics/smd-101/smd-101_user-manual_2456436121.webp)
To Establish a Network Connection to the SMD 101:
1.
Open a TCP socket to port 23 using the player IP address.
NOTE:
If the local system administrators have not changed the value, the
factory-specified default, 192.168.254.254, is the correct value for this field.
2.
The SMD 101 responds with a copyright message including the date, the name of the
product, firmware version, part number, and the current date/time.
a.
If the SMD 101 is not password-protected, the device is ready to accept SIS
commands immediately after it sends the copyright message.
b.
If the SMD 101 is password-protected, a
password
prompt appears below the
copyright message. Proceed to step 3.
3.
If the device is password protected, enter the appropriate administrator or user
password.
a.
If the password is accepted, the device responds with
Login User
or
Login
Administrator
.
b.
If the password is not accepted, the
Password
prompt reappears.
Connection Timeouts
The Ethernet link times out after a designated period of time of no communications. By
default, this timeout value is 5 minutes, but the value can be changed.
NOTE:
Extron recommends leaving the default timeout at 5 minutes and periodically
issuing the
Query
(Q) command to keep the connection active. If there are long
idle periods, disconnect the socket and reopen the connection when another
command must be sent.
114
SMD 101 • Remote Communication and Control
Содержание SMD 101