Status Monitoring and Statistics
ExtremeWare XOS 11.3 Concepts Guide
196
The following sample output displays the current temperature and operating status of the installed
modules and power controllers:
Field Replaceable Units Temp (C) Status
------------------------------------------------
Slot-1 : 10G6X 36.37 Normal
Slot-2 : G60X 35.31 Normal
Slot-3 :
Slot-4 :
Slot-5 :
Slot-6 : G60X 34.68 Normal
Slot-7 : G60X 34.31 Normal
Slot-8 :
MSM-A : MSM-1XL 31.37 Normal
MSM-B : MSM-1XL 29.75 Normal
PSUCTRL-1 :
PSUCTRL-2 : 29.00 Normal
Temp Range: -10.00 (Min), 0.00-50.00 (Normal), 60.00 (Max)
The switch monitors the temperature of each component and generates a warning if the temperature
exceeds the normal operating range. If the temperature exceeds the minimum/maximum limits, the
switch shuts down the overheated module.
System Temperature Output—Summit X450 Switch Only
On a Summit X450 switch, the output includes the current temperature and operating status of the
switch and the XGM-2xn card.
The following sample output displays the current temperature and operating status of the switch:
Field Replaceable Units Temp (C) Status
------------------------------------------------
Switch : SummitX450-24x 42.50 Normal
XGM-2xn-1 :
Temp Range: -10.00 (Min), 0.00-60.50 (Normal), 62.90 (Max)
The switch monitors its temperature and generates a warning if the temperature exceeds the normal
operating range. If the temperature exceeds the maximum limit, the
show switch
output indicates the
switch in an
OPERATIONAL (Overheat)
mode, and the
show temperature
e
output indicates an error
state due to overheat.
Power Supply Temperature—Modular Switches Only
To view the current temperature of the power supplies installed in a BlackDiamond 10K switch or the
BlackDiamond 8800 family of switches, use the following command:
show power {<ps_num>} {detail}
The following sample output displays the temperature information:
PowerSupply 1 information:
...
Содержание ExtremeWare XOS 11.3
Страница 20: ...Contents ExtremeWare XOS 11 3 Concepts Guide 20...
Страница 25: ...1 Using ExtremeWare XOS...
Страница 26: ......
Страница 38: ...ExtremeWare XOS Overview ExtremeWare XOS 11 3 Concepts Guide 38...
Страница 58: ...Accessing the Switch ExtremeWare XOS 11 3 Concepts Guide 58...
Страница 146: ...Configuring Slots and Ports on a Switch ExtremeWare XOS 11 3 Concepts Guide 146...
Страница 218: ...Status Monitoring and Statistics ExtremeWare XOS 11 3 Concepts Guide 218...
Страница 240: ...Virtual LANs ExtremeWare XOS 11 3 Concepts Guide 240...
Страница 248: ...Virtual Routers ExtremeWare XOS 11 3 Concepts Guide 248...
Страница 278: ...Access Lists ACLs ExtremeWare XOS 11 3 Concepts Guide 278...
Страница 288: ...Routing Policies ExtremeWare XOS 11 3 Concepts Guide 288 entry deny_rest if then deny...
Страница 344: ...Security ExtremeWare XOS 11 3 Concepts Guide 344...
Страница 393: ...2 Using Switching and Routing Protocols...
Страница 394: ......
Страница 454: ...Spanning Tree Protocol ExtremeWare XOS 11 3 Concepts Guide 454...
Страница 484: ...Extreme Standby Router Protocol ExtremeWare XOS 11 3 Concepts Guide 484...
Страница 514: ...IPv4 Unicast Routing ExtremeWare XOS 11 3 Concepts Guide 514...
Страница 530: ...IPv6 Unicast Routing ExtremeWare XOS 11 3 Concepts Guide 530...
Страница 538: ...RIP ExtremeWare XOS 11 3 Concepts Guide 538...
Страница 556: ...OSPF ExtremeWare XOS 11 3 Concepts Guide 556...
Страница 566: ...OSPFv3 ExtremeWare XOS 11 3 Concepts Guide 566...
Страница 589: ...3 Appendixes...
Страница 590: ......
Страница 640: ...CNA Agent ExtremeWare XOS 11 3 Concepts Guide 640...
Страница 670: ...Glossary ExtremeWare XOS 11 3 Concepts Guide 670...
Страница 698: ...Index ExtremeWare XOS 11 3 Concepts Guide 698...